Products / CNX-HLA
LED Hospital Light
High efficacy up to 130 lm/W and up to 75 % energy savings, available in 20 W to 40 W configurations with separate up and down light control.
130 lm/Wefficacy
50 / 50up / down split, switched separately
USBport and outlet built in

Product range
3 lumen packages01
Small, medium or large · 20–40 W
One fixture in three lengths: 60 cm for single-bed rooms and examination bays, 93 cm for standard patient rooms, 121 cm for wide bedheads and two-bed rooms.

Lengths and section

Colour temperature
- 3,000 K
- 4,000 K
- 5,000 K
Control
- Toggle switch
- Pull chain
- 0–10 V
- Motion sensor
- ColoursWhite
- Input voltage120–277 V AC
347–480 V AC - Ingress ratingIP40
- Operating temperature−20 to +50 °C




3 lumen packages · 130 lm/WShow
20 W2,600 lm10 W up / 10 W down
30 W3,900 lm15 W up / 15 W down
40 W5,200 lm20 W up / 20 W down
In use
Application examples
Specifications
| Housing | Aluminium, architectural design |
|---|---|
| Lens | Vandal-resistant polycarbonate, white |
| Thermal management | High-grade thermal paste, PCB to housing |
| Ingress rating | IP40 |
| Mounting | Surface or suspension |
| Sizes | S 60.4 cm (20 W), M 93 cm (30 W), L 121.4 cm (40 W); custom length to order |
| Options | Built-in USB port and electrical outlet; toggle or pull-chain switch |
| Up/down split | 50 % up / 50 % down, switched separately |
|---|
| CRI | > 83 |
|---|---|
| Colour temperature | 3000 K, 4000 K or 5000 K |
| Input voltage | 120–277 VAC or 347–480 VAC, 50/60 Hz |
|---|---|
| Power factor | > 0.95 at full load |
| THD | < 13% |
| Operating temperature | −20 °C to +50 °C |
| Surge protection | Built in; 10 kV/10 kA optional |
| Switching cycles | 100,000 |
| Control | 0–10 VDC dimming or motion sensor |
| Emergency | Optional battery backup |
Dimensions & weight
| Model | Length | Width | Height | Weight |
|---|---|---|---|---|
| HLA-020 (S) | 60.4 cm | 8.4 cm | 13.1 cm | — |
| HLA-030 (M) | 93 cm | 8.4 cm | 13.1 cm | — |
| HLA-040 (L) | 121.4 cm | 8.4 cm | 13.1 cm | — |
Ordering information
Part number format
CNX-HLAProduct type301Colour temperature0202WattageP13Input voltageSFC4MountingTGL5SwitchingDIM6ControlS7SizeEMG8Emergency backupExample: CNX-HLA-30-020-P1-SFC-TGL-DIM-S-EMG — the first code in each numbered position; pick one code per position below to build your own
1Colour temperature
2Wattage
3Input voltage
4Mounting
5Switching
6Control
7Size
8Emergency backup
Applications
Health careEducationCommercialAutomotiveLaboratoriesService centresTask lighting
Certifications
ETL (Intertek)CERoHSFCCISO 9001 (SGS)DLC Premium